WASTE CONE D WASTE CONE G "X" 125# ANSI FLANGE RELIEF VALVE OUTLET "X" 125# ANSI FLANGE RELIEF VALVE OUTLET K Spring Operated Main Relief Valve K 125# INLET FLANGE K 250# INLET FLANGE K Pilot Operated Main Relief Valve K 125# INLET FLANGE K 250# INLET FLANGE K Enclosed Waste Cone K Enclosed Waste Cone PUMP RATING
Geothermal Pump and Fire Pump Manufacturing Geothermal Systems and Parts Fire Protection Systems and parts by Geo Systems USA Geo Systems USA Distributor Login Fabricated Waste Cones Contact Us GEO SYSTEMS USA 2435 Dillard St Grand Prairie TX 75051
Fire Pump Performance Characteristics Conform to NFPA 20 NFPA 20 AquaMas Fire Pump Types SNT End Suction SDS Double Suction SKM Multistage 25 50 100 150 200 250 300 400 450 500 750 1000 Waste Cone Buttery Valve Desel Engne Control Panel Pressure Swtch Solenod Valve Releve Valve Casng Releve Valve Electrc Motor Control Panel
driven pumps only Other optional accessories if ordered may also be shipped loose Some common examples are Eccentric tapered suction reducer Concentric tapered dischargeincreaser Flow meter Main relief valve diesel driven pumps Waste cone diesel driven pumps Diesel driven Fire Pumps are furnished with
5 Enclosed discharge overflow cone 6 Eccentric suction reducer 7 Suction pressure gauge 8 Horizontal pump HORIZONTAL FIRE PUMPS ELECTRIC MOTOR DRIVEN / APPROVED RANGE Head PSI 300 250 200 PDN 150 300 H/L/M PDN 200 300 M n enclosed waste cone with glass 3 x5 4 x8 6 x10 8 x12
Pressure relief valves PRVs are crucial components in fire pump systems Their primary role is to protect the system from excessive pressure which can cause damage to pipes fittings and other components Here s a detailed look at their functions and importance
Designed for use with UL/FM Approved Fire Pump Pressure Relief Valves AQUA 40 520 Waste Cone ANSI class 150 Author sylvain Subject Marketing Sheet Created Date 1/30/2019 9 29 12 AM
Fire pump systems are essential components in fire protection providing the necessary water flow and pressure for effective firefighting Enter LIFECO a renowned leader in the fire safety industry specialising in the development manufacturing and delivery of advanced fire pump With LIFECO clients are assured of receiving top tier fire pump systems backed by extensive
Waste Cone Waste cones are designed to provide quick and easy visual confirmation of proper water flow in fireprotection systems Two sight glasses extending from the center of thewaste cone allow users to observe the flow of water and ensure that the system s pumps and other components are working correctly
1a Fire pump electrically powered duty pump 5 Valve 10 Waste cone with sight glass 1b Fire pump diesel powered standby pump 6 Expansion joint 11 Discharge from relief valve 2 Jockey pump 7 Main relief valve 12 Flowmeter 3 From supply tank 8 Check valve/non return valve 13 Discharge from test line
Fire pumps driven by a diesel motor without a heat exchanger cooling system do not require a circulation relief valve because the diesel engines water cooling system takes suction from the discharge of the pump The relief valve waste cone is an acceptable open receptacle for the discharge if the relief valve discharge line discharges to
cone should be used The enclosed cones are fitted with sight glasses to permit the operator to see any waste through them The overflow cones provide inlets suitable for the fitting connected to them and outlets equal to or larger than the minimum waste pipe sizes as specified in the nfpa Stan air release valve nfpa Standards require all
A C FIRE PUMP SYSTEMS Dimensions Fire Pump Fittings & Accessories Supersedes all previous issues CASING RELIEF VALVE Pressure Setting Adjustment Screw Turn Clockwise To Increase Setting INLET Size 3/4" Threaded Temperature Range Water Air to 180°F Max Materials Body & Cover Cast Bronze ASTM B62
Fire pump systems have many auxiliary environmental equipment such as relief valves waste cone flow meters pressure gauges vacuum gauges test valves etc The types and characteristics of these peripheral equipment are determined according to the flow rate and pressure values of the main pumps main reserve
Contractor shall furnish and install an A C Fire Pump system or approved equal UL® listed single stage close coupled 1580 Series Vertical In Line Pump for fire suppression The pump s • Closed waste cone • Flowmeter • Suction control valve Xylem Applied Water Systems a division of Xylem Canada Company 55 Royal Road Guelph
Company Introduction Yuyao Hongfu Fire Protection Equipment Co Ltd was founded in 2015 produce water system fire equipment and is located in Yuyao of Ningbo city Zhejiang kown as " Fire Equipment Town of China" So far Hongfu has a staff of more than 50 including 5 with university or technical secondary school degrees or above Hongfu has a site
Accessories Accessories Fire Pump Flow Meter FM Approval) Pressure Relief Valve UL Listed/ULC Listed Waste Cone Manufactured in Accordance with NFPA 20 Requirements Available for Onshore and Offshore Applications Designed
4 877 978 2090 1973 Whitney Mesa Dr Ste #4 Henderson NV 89014 1868 Anamor Street Redwood City CA 94061 2105 S Hardy Dr Unit 9 Tempe AZ 85282 Email [email protected] Lic #77357
Waste Cone Model LF WC Unit 8 Calibre Industrial Park Laches Close Four Ashes Wolverhampton WV10 7DZ United Kingdom T 44 1902 798 706 F 44 1902 798 679 E sales 1 In line with our policy of continuous product improvement LIFECO reserves the right to modify specifications without prior notice
Address Maxi seal Trading FZE Sharjah Abudhabi United Arab Emirates Mobile 97155 827 3533 971553954373 Email sales
Model WC 1 Waste Cone • Available for Onshore and Offshore Applications • Manufactured in Accordance with NFPA 20 Requirements • Designed for use with UL/FM Approved Fire Pump Pressure Relief Valves • Fusion Bonded Red Epoxy Coated • Ductile Iron ASTM A536 65 • 2 2 316 SS Sight Glasses per WC 1
Waste Cone The Fire Pump Discharge Relief Waste Cone is manufactured in accordance with NFPA 20 requirements The Stainless Steel X140 Pressure Gauge available in sizes and 4 inches is an easily retrofittable solution in applications where visual pressure indication is desired X141 Pressure Gauge Solenoid Valve Direct Acting High Flow/High
Get Newage Series Fire Pump Pressure Relief Valve With Waste Cone Model 50B 4KG1 WC at best price in Mumbai Maharashtra by Inferno Integrated Solutions and more suppliers ID 2849423998373 Newage Series Fire Pump Pressure Relief Valve With Waste Cone Model 50B 4KG1 WC Currently out of Stock Media Water Color red Brand Newage UL
Fire pumps driven by a diesel motor without a heat exchanger cooling system do not require a circulation relief valve because the diesel engines water cooling system takes suction from the discharge of the pump The relief valve waste cone is an acceptable open receptacle for the discharge if the relief valve discharge line discharges to